Gold Member Since 2007
King Best International Holdings Limited

Sch 40, PVC Pipe, PVC manufacturer / supplier in China, offering ASTM D1785 Sch40 PVC-U Potable Water Pipes and BS3505 Pressure Pipes for Cold Potable Water, Wall Fan/Workshop Fan/Electric Fan/Stand Fan/Exhuast Fan/Industrial Ventilation Fans-Fw/ Ffseries, PVC Pipes and PVC Conduit, Fittings, Different Standards/Tubes/Plumbings and so on.

(/ )

Supplier Homepage Product Plastic products ASTM D1785 Sch40 PVC-U Potable Water Pipes and BS3505 Pressure Pipes for Cold Potable Water

ASTM D1785 Sch40 PVC-U Potable Water Pipes and BS3505 Pressure Pipes for Cold Potable Water

FOB Price: Get Latest Price
Min. Order: 500 Pieces
Port: Ningbo, China
Production Capacity: 20X40FT Hc Per Month
Payment Terms: L/C, T/T
Basic Info
  • Model NO.: 1/2′′ to 8′′
  • Connection: Welding
  • Transport Package: by Polybags or Woven Bags
  • Origin: China
  • Material: Plastic
  • Trademark: clients′ logos
  • Specification: 1/2′′ to 8′′
  • HS Code: 39172900
Product Description
We have been producing the following plastic pipes and fittings for 22 years:
1.UPVC electric conduits and fittings ( Chinese Standards, British Standards EN50086 ,DIN standard, Australian Standards AS/NZ2053, AS61386.1.2015, ASTM schedule 40 & 80)
2.UPVC cable trunkings or ductings and fittings (over 70 sizes for different countries)
3.UPVC flexible pipes (UPVC corrugated pipes,Chinese standards,AS/NZ2053)
4.UPVC bends (Chinese GB,AS/NZ2053, AS61386.1.2015).
5.UPVC communication pipes (AS/NZ2053, AS61386.1.2015)6.UPVC drainage/waste water pipes (Chinese GB,ASTM Schedule ,BS4514/5255 ,AS1254PVC stormwater, surface water series and AS1260 DWV PVC fittings);7.UPVC pressure water pipes and fittings (drinking water, ASTM D1785,ASTM D2466 Schedule 40 and Sch 80,  ISO 4422.2 EN standard, )
Contact us for our E-catalogues, pricelists, sample photos or samples,etc.
We also build the moulds by ourselves (injection parts, extrusion parts) for the pipes, trunkings and fittings.
D 1785 - 06
 
TABLE 1  Outside Diameters and Tolerances for PVC Plastic Pipe Schedules 40, 80, and 120, in. (mm)
 
    Tolerances  
     
    Maximum Out-of-Roundness (maximum minus minimum
    diameter) 
Nominal Pipe SizeOutside Diameter   
AverageSchedule 40 sizes 312 in. andSchedule 40 sizes 3 in. and
   over; Schedule 80 sizes 8 in.less;
    
    and overSchedule 80 sizes 6 in. and
     less;
     Schedule 120 sizes all
       
180.405(10.29)60.004 (60.10). . .0.016(0.41)
140.540(13.72)60.004 (60.10). . .0.016(0.41)
380.675(17.14)60.004 (60.10). . .0.016(0.41)
120.840(21.34)60.004 (60.10). . .0.016(0.41)
341.050(26.67)60.004 (60.10). . .0.020(0.51)
11.315(33.40)60.005 (60.13). . .0.020 (0.51)
1141.660(42.16)60.005 (60.13). . .0.024 (0.61)
1121.900(48.26)60.006 (60.15). . .0.024 (0.61)
22.375(60.32)60.006 (60.15). . .0.024 (0.61)
2122.875(73.02)60.007 (60.18). . .0.030 (0.76)
33.500(88.90)60.008 (60.20). . .0.030 (0.76)
3124.000(101.60)60.008 (60.20)0.100 (2.54)0.030 (0.76)
44.500 (114.30)60.009 (60.23)0.100 (2.54)0.030 (0.76)
55.563(141.30)60.010 (60.25)0.100 (2.54)0.060 (1.52)
66.625(168.28)60.011 (60.28)0.100 (2.54)0.070 (1.78)
88.625(219.08)60.015 (60.38)0.150 (3.81)0.090 (2.29)
1010.750(273.05)60.015 (60.38)0.150 (3.81)0.100 (2.54)
1212.750(323.85)60.015 (60.38)0.150 (3.81)0.120 (3.05)
1414.000 (355.6060.015 (60.38)0.200 (5.08). . .
1616.000(406.40)60.019 (60.48)0.320 (8.13). . .
1818.000(457.20)60.019 (60.48)0.360 (9.14). . .
2020.000(508.00)60.023 (60.58)0.400 (10.2). . .
2424.000(609.60)60.031 (60.79)0.480 (12.2). . .
       
 
TABLE 2  Wall Thicknesses and Tolerances for PVC Plastic Pipe, Schedules 40, 80, and 120,A,B in. (mm)
 
     Wall ThicknessA   
Nominal Pipe         
 Schedule 40 Schedule 80 Schedule 120
Size   
         
 MinimumToleranceMinimumToleranceMinimumTolerance
         
180.068(1.73)+0.020 (+0.51)0.095(2.41)+0.020 (+0.51). . .. . .
140.088(2.24)+0.020 (+0.51)0.119 (3.02)+0.020 (+0.51). . .. . .
380.091(2.31)+0.020 (+0.51)0.126(3.20)+0.020 (+0.51). . .. . .
120.109(2.77)+0.020 (+0.51)0.147(3.73)+0.020 (+0.51)0.170(4.32)+0.020 (+0.51)
340.113 (2.87)+0.020 (+0.51)0.154(3.91)+0.020 (+0.51)0.170(4.32)+0.020 (+0.51)
10.133(3.38)+0.020 (+0.51)0.179(4.55)+0.021 (+0.53)0.200(5.08)+0.024 (+0.61)
1140.140(3.56)+0.020 (+0.51)0.191(4.85)+0.023 (+0.58)0.215(5.46)+0.026 (+0.66)
1120.145(3.68)+0.020 (+0.51)0.200(5.08)+0.024 (+0.61)0.225(5.72)+0.027 (+0.68)
20.154(3.91)+0.020 (+0.51)0.218(5.54)+0.026 (+0.66)0.250(6.35)+0.030 (+0.76)
2120.203(5.16)+0.024 (+0.61)0.276(7.01)+0.033 (+0.84)0.300(7.62)+0.036 (+0.91)
30.216(5.49)+0.026 (+0.66)0.300(7.62)+0.036 (+0.91)0.350(8.89)+0.042 (+1.07)
3120.226(5.74)+0.027 (+0.68)0.318(8.08)+0.038 (+0.96)0.350(8.89)+0.042 (+1.07)
40.237(6.02)+0.028 (+0.71)0.337(8.56)+0.040 (+1.02)0.437 (11.10)+0.052 (+1.32)
50.258(6.55)+0.031 (+0.79)0.375(9.52)+0.045 (+1.14)0.500(12.70)+0.060 (+1.52)
60.280 (7.11)+0.034 (+0.86)0.432(10.97)+0.052 (+1.32)0.562(14.27)+0.067 (+1.70)
80.322(8.18)+0.039 (+0.99)0.500(12.70)+0.060 (+1.52)0.718(18.24)+0.086 (+2.18)
100.365(9.27)+0.044 (+1.12)0.593(15.06)+0.071 (+1.80)0.843(21.41)+0.101 (+2.56)
120.406(10.31)+0.049 (+1.24)0.687(17.45)+0.082 (+2.08)1.000(25.40)+0.120 (+3.05)
140.437 (11.10)+0.053 (+1.35)0.750(19.05)+0.090 (+2.29). . .. . .
160.500(12.70)+0.060 (+1.52)0.843(21.41)+0.101 (+2.57). . .. . .
180.562(14.27)+0.067 (+1.70)0.937(23.80)+0.112 (+2.84). . .. . .
200.593(15.06)+0.071 (+1.80)1.031(26.19)+0.124 (+3.15). . .. . .
240.687(17.45)+0.082 (+2.08)1.218(30.94)+0.146 (+3.71). . .. . .
          
 
D 1785 - 06
 
 
TABLE 3 Sustained Pressure Test Conditions for Water at 73°F (23°C) for PVC Plastic Pipe, Schedule 40
 
Nominal  Pressure Required for TestA 
PVC1120   
Pipe   
SizePVC1220PVC2116PVC2112PVC2110
 PVC2120   
      
in.   psi 
     
18169013601130930
14164013101090900
3813101050870720
1212501000840690
341010810680550
1950760630520
114770620520420
112690560460380
2580470390320
212640510430350
3590440370300
312500400340280
4470370310260
5410330270220
6370300250200
8330260220180
10300240200160
12280220180150
14270220180150
16270220180150
18270220180150
20260210170140
24250200170140
      
in.   MPa 
     
1811.659.387.796.41
1411.319.037.526.21
389.037.246.004.96
128.626.895.794.76
346.965.584.693.79
16.555.244.343.59
1145.314.273.592.90
1124.763.863.172.62
24.003.242.692.21
2124.413.522.962.41
34.073.032.552.07
3123.452.762.341.93
43.242.552.141.79
52.832.281.861.52
62.552.071.721.38
82.281.791.521.24
102.071.651.381.10
121.931.521.241.03
141.891.541.261.05
161.891.541.261.05
181.891.541.261.05
201.821.471.190.98
241.751.401.190.98

A The fiber stresses used to derive these test pressures are as follows:
 
 psiMPa
PVC1120420029.0
PVC1220420029.0
PVC2120420029.0
PVC2116336023.2
PVC2112280019.3
PVC2110230015.9
 
 
TABLE 4 Sustained Pressure Test Conditions for Water at 73°F (23°C) for PVC Plastic Pipe, Schedule 80
 
Nominal  Pressure Required for TestA 
PVC1120   
Pipe   
SizePVC1220PVC2116PVC2112PVC2110
 PVC2120   
      
in.   psi 
     
182570206017201410
142370190015801300
381930154012901060
12178014301190980
3414401160960790
113201060880720
1141090870730600
112990790660540
2850680570460
212890710590490
3790630520430
312730580480400
4680540450370
5610490400330
6590470390320
8520410340280
10490390330270
12480380320260
14470380320260
16470370310260
18460370310250
20460370300250
24450360300250
      
in.   MPa 
     
1817.7214.2111.869.72
1416.3413.1010.908.96
3813.3110.628.897.31
1212.279.868.206.76
349.938.006.625.45
19.107.316.074.96
1147.526.005.034.14
1126.834.964.553.72
25.864.693.933.17
2126.144.904.073.38
35.454.343.592.96
3125.034.003.312.76
44.693.723.102.55
54.213.382.762.28
64.073.242.692.21
83.592.832.341.93
103.382.692.281.86
123.312.622.211.79
143.292.662.241.82
163.292.592.171.82
183.222.592.171.75
203.222.592.101.75
243.152.522.101.75


  
Send your message to this supplier
Avatar
Mr. George Wu
Export Manager
*From:
To: Mr. George Wu
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Find Similar Products By Category