Basic Info.

Model NO.
1/2′′ to 8′′
Specification
1/2′′ to 8′′
Trademark
clients′ logos
Origin
China
HS Code
39172900
Production Capacity
20X40FT Hc Per Month

Product Description

We have been producing the following plastic pipes and fittings for 28 years:
  1. VALVE:
PVC VALVES AND FITTINGS
 CPVC VALVES AND FITTINGS
  1. PRESSURE
 PVC PRESSURE PIPES AND FITTINGS PN10 (ISO1452)
 PVC PRESSURE PIPES AND FITTINGS TYPE II
 PVC PRESSURE PIPES AND FITTINGS PN16 (DIN8063)
 PVC PRESSURE PIPES AND THREAD FITTINGS BS STANDARD
 PVC SCH40 PIPES AND FITTINGS (ASTM D1785,D2466)
 PVC SCH80 PIPES AND FITTINGS (ASTM D2467)
 PVC PRESSURE FITTINGS (BS4346)
 PVC PRESSURE FITTINGS (JIS STANDARD)
 PVC PRESSURE PIPES AND FITTINGS (AS/NZS1477)
 PVC PRESSURE PIPES WITH GASKET
 PP COMPRESSION FITTINGS VALVES AND FILTERS (EN ISO1587,AS/NZS4129)
 PP THREAD FITTINGS
 PE BUTT WELDING AND SOCKET WELDING FITTINGS
 PE ELECTROFUSION FITTING SERIES
 PE BALL VALVE SERIES
  1. PRESSURE FOR HOT AND COLD
 CPVC SCH80 PIPES AND FITTINGS (ASTM F439)
 CPVC DIN PIPES AND FITTINGS
 CPVC CTS PIPES AND FITTINGS (ASTM D2846)
 PPR DIN PIPES AND FITTINGS (DIN8077/8088)
 PPH THREAD FITTINGS (IRAM 13478)
  1. DRAINAGE
 PVC DRAINAGE PIPES AND FITTINGS (BS1329/BS1401)
 PVC DRAINAGE FITTINGS WITH GASKET (EN1401)
 PVC DRAINAGE FITTINGS (ISO3633)
 PVC DWV DRAINAGE FITTINGS (ASTM D1785, D2665)
PVC DWV FITTINGS (NSF/ANSI STANDARD 14)
 PVC DWV FITTINGS
 PVC DWV DRAINAGE FITTINGS (AS/NZS1260)
 PVC-U PIPES AND FITTINGS FOR STORMWATER AS/NZS1254
  1. RAIN GUTTER
 PVC GUTTERS AND FITTINGS (BS EN607/EN12200/EN1462)
  1. ELECTRIC CONDUITS AND FITTINGS
 PVC INSULATING ELECTRICAL PIPES AND FITTINGS
 PVC INSULATING ELECTRICAL PIPES AND FITTINGS(AS/NZS2053/ AS61386.1.2015,)
 PVC INSULATING ELECTRICAL PIPES AND FITTINGS(BS EN 61386-21/ BS EN50086)
PVC ELECTRICAL PIPES AND FITTINGS(ASTM SCH40 & 80,UL651)
PVC FLEXIBLE PIPES (AS/NZ2053)
PVC COMMUNICATION PIPES(AS/NZ2053, AS61386.1.2015)
PVC SWEEP BENDS (AS/NZ2053, AS61386.1.2015)
PVC CABLE TRUNKINGS OR DUCTINGS AND FITTINGS (over 70 sizes for different countries)

We also build the moulds by ourselves (injection parts, extrusion parts) for the pipes, conduits, trunkings and fittings.

If you are interested in any of the above products, please contact us for our PDF catalogs, pricelists, sample photos or samples, etc.


D 1785 - 06
 
TABLE 1  Outside Diameters and Tolerances for PVC Plastic Pipe Schedules 40, 80, and 120, in. (mm)
 
        Tolerances    
         
        Maximum Out-of-Roundness (maximum minus minimum
        diameter)  
Nominal Pipe Size Outside Diameter      
Average Schedule 40 sizes 312 in. and Schedule 40 sizes 3 in. and
      over; Schedule 80 sizes 8 in. less;
       
        and over Schedule 80 sizes 6 in. and
          less;
          Schedule 120 sizes all
             
18 0.405 (10.29) 60.004 (60.10) . . . 0.016 (0.41)
14 0.540 (13.72) 60.004 (60.10) . . . 0.016 (0.41)
38 0.675 (17.14) 60.004 (60.10) . . . 0.016 (0.41)
12 0.840 (21.34) 60.004 (60.10) . . . 0.016 (0.41)
34 1.050 (26.67) 60.004 (60.10) . . . 0.020 (0.51)
1 1.315 (33.40) 60.005 (60.13) . . . 0.020 (0.51)
114 1.660 (42.16) 60.005 (60.13) . . . 0.024 (0.61)
112 1.900 (48.26) 60.006 (60.15) . . . 0.024 (0.61)
2 2.375 (60.32) 60.006 (60.15) . . . 0.024 (0.61)
212 2.875 (73.02) 60.007 (60.18) . . . 0.030 (0.76)
3 3.500 (88.90) 60.008 (60.20) . . . 0.030 (0.76)
312 4.000 (101.60) 60.008 (60.20) 0.100 (2.54) 0.030 (0.76)
4 4.500 (114.30) 60.009 (60.23) 0.100 (2.54) 0.030 (0.76)
5 5.563 (141.30) 60.010 (60.25) 0.100 (2.54) 0.060 (1.52)
6 6.625 (168.28) 60.011 (60.28) 0.100 (2.54) 0.070 (1.78)
8 8.625 (219.08) 60.015 (60.38) 0.150 (3.81) 0.090 (2.29)
10 10.750 (273.05) 60.015 (60.38) 0.150 (3.81) 0.100 (2.54)
12 12.750 (323.85) 60.015 (60.38) 0.150 (3.81) 0.120 (3.05)
14 14.000 (355.60 60.015 (60.38) 0.200 (5.08) . . .
16 16.000 (406.40) 60.019 (60.48) 0.320 (8.13) . . .
18 18.000 (457.20) 60.019 (60.48) 0.360 (9.14) . . .
20 20.000 (508.00) 60.023 (60.58) 0.400 (10.2) . . .
24 24.000 (609.60) 60.031 (60.79) 0.480 (12.2) . . .
             
 
TABLE 2  Wall Thicknesses and Tolerances for PVC Plastic Pipe, Schedules 40, 80, and 120,A,B in. (mm)
 
          Wall ThicknessA      
Nominal Pipe                  
  Schedule 40   Schedule 80   Schedule 120
Size      
                 
  Minimum Tolerance Minimum Tolerance Minimum Tolerance
                 
18 0.068 (1.73) +0.020 (+0.51) 0.095 (2.41) +0.020 (+0.51) . . . . . .
14 0.088 (2.24) +0.020 (+0.51) 0.119 (3.02) +0.020 (+0.51) . . . . . .
38 0.091 (2.31) +0.020 (+0.51) 0.126 (3.20) +0.020 (+0.51) . . . . . .
12 0.109 (2.77) +0.020 (+0.51) 0.147 (3.73) +0.020 (+0.51) 0.170 (4.32) +0.020 (+0.51)
34 0.113 (2.87) +0.020 (+0.51) 0.154 (3.91) +0.020 (+0.51) 0.170 (4.32) +0.020 (+0.51)
1 0.133 (3.38) +0.020 (+0.51) 0.179 (4.55) +0.021 (+0.53) 0.200 (5.08) +0.024 (+0.61)
114 0.140 (3.56) +0.020 (+0.51) 0.191 (4.85) +0.023 (+0.58) 0.215 (5.46) +0.026 (+0.66)
112 0.145 (3.68) +0.020 (+0.51) 0.200 (5.08) +0.024 (+0.61) 0.225 (5.72) +0.027 (+0.68)
2 0.154 (3.91) +0.020 (+0.51) 0.218 (5.54) +0.026 (+0.66) 0.250 (6.35) +0.030 (+0.76)
212 0.203 (5.16) +0.024 (+0.61) 0.276 (7.01) +0.033 (+0.84) 0.300 (7.62) +0.036 (+0.91)
3 0.216 (5.49) +0.026 (+0.66) 0.300 (7.62) +0.036 (+0.91) 0.350 (8.89) +0.042 (+1.07)
312 0.226 (5.74) +0.027 (+0.68) 0.318 (8.08) +0.038 (+0.96) 0.350 (8.89) +0.042 (+1.07)
4 0.237 (6.02) +0.028 (+0.71) 0.337 (8.56) +0.040 (+1.02) 0.437 (11.10) +0.052 (+1.32)
5 0.258 (6.55) +0.031 (+0.79) 0.375 (9.52) +0.045 (+1.14) 0.500 (12.70) +0.060 (+1.52)
6 0.280 (7.11) +0.034 (+0.86) 0.432 (10.97) +0.052 (+1.32) 0.562 (14.27) +0.067 (+1.70)
8 0.322 (8.18) +0.039 (+0.99) 0.500 (12.70) +0.060 (+1.52) 0.718 (18.24) +0.086 (+2.18)
10 0.365 (9.27) +0.044 (+1.12) 0.593 (15.06) +0.071 (+1.80) 0.843 (21.41) +0.101 (+2.56)
12 0.406 (10.31) +0.049 (+1.24) 0.687 (17.45) +0.082 (+2.08) 1.000 (25.40) +0.120 (+3.05)
14 0.437 (11.10) +0.053 (+1.35) 0.750 (19.05) +0.090 (+2.29) . . . . . .
16 0.500 (12.70) +0.060 (+1.52) 0.843 (21.41) +0.101 (+2.57) . . . . . .
18 0.562 (14.27) +0.067 (+1.70) 0.937 (23.80) +0.112 (+2.84) . . . . . .
20 0.593 (15.06) +0.071 (+1.80) 1.031 (26.19) +0.124 (+3.15) . . . . . .
24 0.687 (17.45) +0.082 (+2.08) 1.218 (30.94) +0.146 (+3.71) . . . . . .
                   
 
D 1785 - 06
 
 
TABLE 3 Sustained Pressure Test Conditions for Water at 73°F (23°C) for PVC Plastic Pipe, Schedule 40
 
Nominal     Pressure Required for TestA  
PVC1120      
Pipe      
Size PVC1220 PVC2116 PVC2112 PVC2110
  PVC2120      
           
in.       psi  
         
18 1690 1360 1130 930
14 1640 1310 1090 900
38 1310 1050 870 720
12 1250 1000 840 690
34 1010 810 680 550
1 950 760 630 520
114 770 620 520 420
112 690 560 460 380
2 580 470 390 320
212 640 510 430 350
3 590 440 370 300
312 500 400 340 280
4 470 370 310 260
5 410 330 270 220
6 370 300 250 200
8 330 260 220 180
10 300 240 200 160
12 280 220 180 150
14 270 220 180 150
16 270 220 180 150
18 270 220 180 150
20 260 210 170 140
24 250 200 170 140
           
in.       MPa  
         
18 11.65 9.38 7.79 6.41
14 11.31 9.03 7.52 6.21
38 9.03 7.24 6.00 4.96
12 8.62 6.89 5.79 4.76
34 6.96 5.58 4.69 3.79
1 6.55 5.24 4.34 3.59
114 5.31 4.27 3.59 2.90
112 4.76 3.86 3.17 2.62
2 4.00 3.24 2.69 2.21
212 4.41 3.52 2.96 2.41
3 4.07 3.03 2.55 2.07
312 3.45 2.76 2.34 1.93
4 3.24 2.55 2.14 1.79
5 2.83 2.28 1.86 1.52
6 2.55 2.07 1.72 1.38
8 2.28 1.79 1.52 1.24
10 2.07 1.65 1.38 1.10
12 1.93 1.52 1.24 1.03
14 1.89 1.54 1.26 1.05
16 1.89 1.54 1.26 1.05
18 1.89 1.54 1.26 1.05
20 1.82 1.47 1.19 0.98
24 1.75 1.40 1.19 0.98

A The fiber stresses used to derive these test pressures are as follows:
 
  psi MPa
PVC1120 4200 29.0
PVC1220 4200 29.0
PVC2120 4200 29.0
PVC2116 3360 23.2
PVC2112 2800 19.3
PVC2110 2300 15.9
 
 
TABLE 4 Sustained Pressure Test Conditions for Water at 73°F (23°C) for PVC Plastic Pipe, Schedule 80
 
Nominal     Pressure Required for TestA  
PVC1120      
Pipe      
Size PVC1220 PVC2116 PVC2112 PVC2110
  PVC2120      
           
in.       psi  
         
18 2570 2060 1720 1410
14 2370 1900 1580 1300
38 1930 1540 1290 1060
12 1780 1430 1190 980
34 1440 1160 960 790
1 1320 1060 880 720
114 1090 870 730 600
112 990 790 660 540
2 850 680 570 460
212 890 710 590 490
3 790 630 520 430
312 730 580 480 400
4 680 540 450 370
5 610 490 400 330
6 590 470 390 320
8 520 410 340 280
10 490 390 330 270
12 480 380 320 260
14 470 380 320 260
16 470 370 310 260
18 460 370 310 250
20 460 370 300 250
24 450 360 300 250
           
in.       MPa  
         
18 17.72 14.21 11.86 9.72
14 16.34 13.10 10.90 8.96
38 13.31 10.62 8.89 7.31
12 12.27 9.86 8.20 6.76
34 9.93 8.00 6.62 5.45
1 9.10 7.31 6.07 4.96
114 7.52 6.00 5.03 4.14
112 6.83 4.96 4.55 3.72
2 5.86 4.69 3.93 3.17
212 6.14 4.90 4.07 3.38
3 5.45 4.34 3.59 2.96
312 5.03 4.00 3.31 2.76
4 4.69 3.72 3.10 2.55
5 4.21 3.38 2.76 2.28
6 4.07 3.24 2.69 2.21
8 3.59 2.83 2.34 1.93
10 3.38 2.69 2.28 1.86
12 3.31 2.62 2.21 1.79
14 3.29 2.66 2.24 1.82
16 3.29 2.59 2.17 1.82
18 3.22 2.59 2.17 1.75
20 3.22 2.59 2.10 1.75
24 3.15 2.52 2.10 1.75


  

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier